M50 SERIES

Pocket

Feature

Packed type

Free from any fear of burnout or insulation degradation as the coil and movable core do not come into contact with fluid.

Safe explosion-proof construction

Explosion-proof type valves certified by the Ministry of Labor.

Highly durable

A mechanical life of five million operations or more is expectable.

Manual check is possible

Manual operation is possible. This mode can be used for operation check or switching in case of emergency.

Standard specification

FLUID
CLEAN AIR
FLUID TEMPERATURE
-20 – 60 deg.C
AMBIENT TEMPERATURE
-20 – 60 deg.C
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10,-15%
WORKING PRESSURE
0 ~ 0.99MPa
Cv. FLOW FACTOR
0.18
ELECTRICAL SPECIFICATIONS
See below

STANDARD VOLTAGE

AC DC
V/Hz INRUSH A HOLDING A V A
GENERAL PURPOSE TYPE 1 , EXPLOSION-PROOF TYPE E1 COIL INSULATION CLASS : B
100/50 2.8 0.50 24 0.91
100/60 3.1 0.56 48 0.53
110/60 2.6 0.46 100 0.24
200/50 1.4 0.25 110 0.26
200/60 1.6 0.28 125 0.20
220/60 1.3 0.23

Product images

M50 AC GENERAL PURPOSE TYPE

M50 – 8–10 AC GENERAL PURPOSE TYPE
NOMINAL DIAMETER H
8 148
10 148

M50 DC GENERAL PURPOSE TYPE

M50 – 8–10 DC GENERAL PURPOSE TYPE
NOMINAL DIAMETER H
8 172
10 172

M50 AC EXPLOSION-PROOF TYPE

M50 – 8–10 AC EXPLOSION-PROOF TYPE
NOMINAL DIAMETER H
8 182
10 182

M50 DC EXPLOSION-PROOF TYPE

M50 – 8–10 DC EXPLOSION-PROOF TYPE
NOMINAL DIAMETER H
8 186
10 186

Download