Feature
- Since the pilot valve diaphragm and directly, you can use 0 or differential pressure.
- Ⅱ B + H2T6 Exd explosion-proof explosion-proof test in Japan. It is available in a hydrogen atmosphere.
- Mass flow rate can be obtained even in a small size.(CV value:Up to 13.0)
Precautions
- Permissible tilt angle attachment is less than 30 degrees both left and right front and rear.
Standard specification
- Fluid
- Such as water, oil, air, inert gas
- Working pressure
- Air and gas 0~0.99MPa
- Fluid temperature
- -10℃~60℃(That it does not freeze)
- Ambient temperature
- -10℃~60℃(That it does not freeze)
- Electrical ratings
- Continuity
- The allowable voltage fluctuation rate
- +10%,-15%
- Current value
- Following Table
WORKING PRESSURE
Insulation type H species |
AC |
DC |
V/Hz |
Start-up A |
Power W |
V |
Excitation A |
Power W |
100V 50/60 |
0.15 |
16 |
12 |
1.03 |
18 |
110V 50/60 |
0.16 |
18 |
24 |
0.65 |
18 |
120V 50/60 |
0.17 |
21 |
48 |
0.33 |
18 |
200V 50/60 |
0.07 |
14 |
100 |
0.16 |
18 |
220V 50/60 |
0.08 |
18 |
110 |
0.18 |
21 |
|
|
|
125 |
0.20 |
27 |
|
|
|
200 |
0.08 |
18 |
|
|
|
220 |
0.09 |
21 |