Capable of preventing changes in operation by power failure.
Should power failure occur after the start of operation, the valve does not change its operating position. Therefore, accidents due to power failure can be prevented.
No loss in electric power.
Very economical since the valves are designed to reduce power consumption to about 1/3 that with our former products.
Economical and free from anxiety.
Quite safe without burnout and insulation degradation as the temperature rise of the coil is very low.
Standard specification
FLUID
CLEAN AIR
FLUID TEMPERATURE
-20~60℃
AMBIENT TEMPERATURE
-20~60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10,-15%
WORKING PRESSURE , Cv. FLOW FACTOR
See below
ELECTRICAL SPECIFICATIONS
See below
WORKING PRESSURE, Cv. FLOW FACTOR
ORIFICE TYPE
ORIFICE SIZE
WORKING PRESSURE
Cv. FLOW FACTOR
BLANK
1.6
0~0.99MPa
0.084
01
3.0
0~0.4MPa
0.22
ELECTRICAL SPECIFICATIONS
AC
DC
V/Hz
A
V
A
GENERAL PURPOSE TYPE 12RPS, EXPLOSION-PROOF TYPE E12PRS
COIL INSULATION CLASS : B
100/50
0.052
24
0.260
100/60
0.052
48
0.120
110/60
0.058
100
0.062
200/50
0.040
110
0.067
200/60
0.040
125
0.076
220/60
0.043
M00DU GENERAL PURPOSE TYPE
M00DU-6~10 GENERAL PURPOSE TYPE(MANUAL OPERATION , TERMINAL BOX)