M65G SERIES

Pocket

Feature

Wide range of applications.

Can be used for a wider range of applications because valve sizes from 3/8″ to 1-1/4″ are available.

Manual check is possible.

Manual operation is possible. This mode can be used for operation check or switching in case of emergency.

Standard specification

FLUID
CLEAN AIR
FLUID TEMPERATURE
-20℃ ~ 60℃
AMBIENT TEMPERATURE
-20℃ ~ 60℃
DUTY CYCLE
100% CONTINUOUSLY RATED
OPERATING VOLTAGE RANGE
+10%,-15%
WORKING PRESSURE
0.1 ~ 0.9MPa
Cv. FLOW FACTOR
See below
ELECTRICAL SPECIFICATIONS
See below

Cv. FLOW FACTOR

NOMINAL DIAMETER 10 15 20 25 32
Cv. FLOW FACTOR 2.0 2.5 5.0 12.0 12.0

ELECTRICAL SPECIFICATIONS

AC DC
V/Hz INRUSH A HOLDING A V A
GENERAL PURPOSE TYPE 12PU,EXPLOSION-PROOF TYPE E12PU COIL INSULATION CLASS : B
100/50 0.27 0.16 24 0.33
100/60 0.25 0.13 48 0.15
110/60 0.25 0.15 100 0.072
200/50 0.14 0.08 110 0.08
200/60 0.13 0.07 125 0.06
220/60 0.13 0.08

Product Image

M65G GENERAL PURPOSE TYPE

M65G-10 ~ 32 GENERAL PURPOSE TYPE
NOMINAL DIAMETER MOUNTING LENGTH H
10 87.5 182
15 87.5 182
20 110 225
25 140 264
32 140 264

M65G EXPLOSION-PROOF TYPE

M65G-10 ~ 32 EXPLOSION-PROOF TYPE
NOMINAL DIAMETER MOUNTING LENGTH H
10 87.5 195
15 87.5 195
20 110 237
25 140 276
32 140 276

M65G HYDROGEN EXPLOSION-PROOF TYPE

M65G-10 ~ 32 HYDROGEN EXPLOSION-PROOF TYPE
NOMINAL DIAMETER MOUNTING LENGTH H
10 87.5 218
15 87.5 218
20 110 260
25 140 299
32 140 299

DESCRIPTION OF OPERATION

Download