Feature
- Mass flow rate can be obtained even in a small size. (Cv value:Up to 12.6)
- Mounting orientation freedom. (360 ℃)
Precautions
- For pilot-operated, should be able to ensure minimum operating differential pressure 0.05MPa or more times.
Standard specification
- Fluid
- Such as water, oil, air, inert gas
- Working pressure
- Gas 0.05~0.9MPa
Liquid0.05~1.6MPa
- Differential pressure actuated
- 0.05MPa or more full-time
- Fluid temperature
- -20℃~60℃
- Ambient temperature
- -20℃~60℃(That the fluid does not freeze but)
- Electrical ratings
- Continuity
- The allowable voltage fluctuation rate
- +10%,-15%
- Current value
- Following Table
Current value
Current value(General Format 12PG solenoid,E12PU explosion-proof) |
Insulation type B species |
AC |
DC |
V/Hz |
Start-up A |
Excitation A |
V |
A |
100/50 |
0.27 |
0.16 |
24 |
0.33 |
100/60 |
0.25 |
0.13 |
48 |
0.15 |
110/60 |
0.25 |
0.15 |
100 |
0.072 |
200/50 |
0.14 |
0.08 |
110 |
0.08 |
200/60 |
0.13 |
0.07 |
125 |
0.06 |
220/60 |
0.13 |
0.08 |
|
|